Plutonium Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu in EP 60/61 Containers
Title | Plutonium Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu in EP 60/61 Containers PDF eBook |
Author | |
Publisher | |
Pages | 80 |
Release | 1990 |
Genre | |
ISBN |
This user's manual is addressed to the Savannah River Site personnel (routine operators and supervisors) who perform measurements with the Pu-238 isotopic analysis system. Each chapter begins with a table of contents that lists the section title, illustrations, and tabular data presented in that chapter. The first chapter in this manual is an introduction to the system. Chapter 2 lists required settings for the system's commercial nuclear instrument modules. System operating procedures are given in Chapter 3. Chapter 4 contains routine and supervisorial operator interactions. Chapter 5 describes the system's short- and long-printout output formats. Chapter 6 gives instructions for changing system parameters. Error messages are listed and described Chapter 7. Chapter 8 contains a reference article on measuring relative plutonium isotopics in plutonium samples enriched in Pu-238. All commercial items mentioned in this manual are assumed to be functioning correctly for the purposes of system operation. Users are referred to individual equipment manufacturers' manuals for details of operation, trouble-shooting, and maintenance of this commercial equipment.
Plutonium Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu in EP 60
Title | Plutonium Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu in EP 60 PDF eBook |
Author | |
Publisher | |
Pages | 285 |
Release | 1991 |
Genre | |
ISBN |
This software manual is addressed to the Westinghouse Hanford's Radioisotope Power Systems Facility personnel (programmers and supervisors) who maintain the software on the Pu-238 isotopic analysis system. The document is divided into two parts. Part 1 describes the computer codes that control the system, analyze the spectral data, and determine the relative plutonium abundances. Part 2 contains the software listing of the analysis codes.
Plutonium Isotopic Analysis System for Plutonium Samples Enriched in 238Pu in EP 60
Title | Plutonium Isotopic Analysis System for Plutonium Samples Enriched in 238Pu in EP 60 PDF eBook |
Author | |
Publisher | |
Pages | 285 |
Release | 1991 |
Genre | |
ISBN |
This software manual is addressed to the Westinghouse Hanford's Radioisotope Power Systems Facility personnel (programmers and supervisors) who maintain the software on the Pu-238 isotopic analysis system. The document is divided into two parts. Part 1 describes the computer codes that control the system, analyze the spectral data, and determine the relative plutonium abundances. Part 2 contains the software listing of the analysis codes.
Plutonium Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu in EP 60/61 and Fuel-clad Containers
Title | Plutonium Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu in EP 60/61 and Fuel-clad Containers PDF eBook |
Author | |
Publisher | |
Pages | 72 |
Release | 1991 |
Genre | |
ISBN |
This user's manual is addressed to the Hanford Site personnel (routine operators and supervisors) who perform measurements with the Pu-238 isotopic analysis system. Each chapter begins with a table of contents that lists the section titles, illustrations, and tabular data presented in that chapter. The first chapter in this manual is an introduction to the system. Chapter 2 lists required settings for the system's commercial nuclear instrument modules. System operating procedures are given in Chapter 3. Chapter 4 contains routine and supervisorial operator interactions. Chapter 5 describes the system's short- and long-printout output formats. Chapter 6 gives instructions for changing system parameters. Error messages are listed and described in Chapter 7. Chapter 8 contains reference articles on measuring relative plutonium isotopics in solid samples.
An Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu
Title | An Isotopic Analysis System for Plutonium Samples Enriched in Sup 238 Pu PDF eBook |
Author | |
Publisher | |
Pages | 7 |
Release | 1991 |
Genre | |
ISBN |
We have designed and built a gamma-ray spectrometer system that measures the relative plutonium isotopic abundances of plutonium oxide enriched in 238Pu. The first system installed at Westinghouse Savannah River Company was tested and evaluated on plutonium oxide in stainless steel EP60/61 containers. 238Pu enrichments ranged from 20% to 85%. Results show that 200 grams of plutonium oxide in an EP60.61 container can be measured with {plus minus}0.3% precision and better than {plus minus}1.0% accuracy in the specific power using a counting time of 50 minutes. 3 refs., 2 figs.
Energy Research Abstracts
Title | Energy Research Abstracts PDF eBook |
Author | |
Publisher | |
Pages | 754 |
Release | 1993 |
Genre | Power resources |
ISBN |
Plutonium Isotopic Measurement for Small Product Samples
Title | Plutonium Isotopic Measurement for Small Product Samples PDF eBook |
Author | |
Publisher | |
Pages | |
Release | 1983 |
Genre | |
ISBN |
An automated at-line plutonium isotopic analysis system for small-product plutonium samples in the range of 10 to 1000 .mu.g has been developed. The analysis is based on low-energy gamma rays at 43.48 keV (238Pu), 45.23 keV (24°Pu), 51.63 keV (239Pu), 64.83 keV (241Pu-237U), 129.3 keV (239Pu), and 148.6 keV (241Pu). Within a 20-ks counting time, we demonstrated that for plutonium masses> 600 .mu.g the precision is