National Dam Inspection Program. Lewis Lake Dam (NDI-ID Number PA-00061, DER-ID Number 58-7), Susquehanna River Basin, Susquehanna County, Pennsylvania. Phase I Inspection Report

National Dam Inspection Program. Lewis Lake Dam (NDI-ID Number PA-00061, DER-ID Number 58-7), Susquehanna River Basin, Susquehanna County, Pennsylvania. Phase I Inspection Report
Title National Dam Inspection Program. Lewis Lake Dam (NDI-ID Number PA-00061, DER-ID Number 58-7), Susquehanna River Basin, Susquehanna County, Pennsylvania. Phase I Inspection Report PDF eBook
Author Hendrik Jongsma
Publisher
Pages 106
Release 1980
Genre
ISBN

Download National Dam Inspection Program. Lewis Lake Dam (NDI-ID Number PA-00061, DER-ID Number 58-7), Susquehanna River Basin, Susquehanna County, Pennsylvania. Phase I Inspection Report Book in PDF, Epub and Kindle

Based on the visual inspection, past performance and the available engineering data, the dam and its appurtenant structures appear to be in fair condition. In accordance with the Corps of Engineers' evaluation guidelines, the size classification of this dam is small and the hazard classification is high. These classifications indicate that the Spillway Design Flood (SDF) should be in the range of one-half the Probable Maximum Flood (PMF) to the full PMF. The recommended SDF for this structure is one-half the PMF. The spillway capacity is adequate for passing only 10 percent of the PMF peak inflow without overtopping the dam. The spillway is considered to be seriously inadequate. The dam is therefore unsafe, non-emergency.

National Dam Inspection Program. Lake Walter Dam (NDI I.D. Number PA-0080 DER I.D. Number 058-135) Susquehanna River Basin. Tributary of Messhoppen Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report

National Dam Inspection Program. Lake Walter Dam (NDI I.D. Number PA-0080 DER I.D. Number 058-135) Susquehanna River Basin. Tributary of Messhoppen Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report
Title National Dam Inspection Program. Lake Walter Dam (NDI I.D. Number PA-0080 DER I.D. Number 058-135) Susquehanna River Basin. Tributary of Messhoppen Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report PDF eBook
Author Lawrence D. Andersen
Publisher
Pages 64
Release 1981
Genre
ISBN

Download National Dam Inspection Program. Lake Walter Dam (NDI I.D. Number PA-0080 DER I.D. Number 058-135) Susquehanna River Basin. Tributary of Messhoppen Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report Book in PDF, Epub and Kindle

Lake Walter Dam is located on Spring Run, approximately one mile upstream of its confluence with Meshoppen Creek in Springville Township, Susquehanna County, Pennsylvania. The condition of Lake Walter Dam is considered to be good. The only significant condition noted which requires further attention is the lack of erosion protection in the emergency spillway discharge channel. The swampy condition at the toe of the dam is not considered to be significant at this time; however, the condition should be monitored to document if seepage is developing.

National Dam Inspection Program. Maple Lake Dam (NDI ID Number PA-01026, DER ID Number 57-38), Susquehanna River Basin, Branch of Blackwater Run, Sullivan County, Pennsylvania. Phase I Inspection Report

National Dam Inspection Program. Maple Lake Dam (NDI ID Number PA-01026, DER ID Number 57-38), Susquehanna River Basin, Branch of Blackwater Run, Sullivan County, Pennsylvania. Phase I Inspection Report
Title National Dam Inspection Program. Maple Lake Dam (NDI ID Number PA-01026, DER ID Number 57-38), Susquehanna River Basin, Branch of Blackwater Run, Sullivan County, Pennsylvania. Phase I Inspection Report PDF eBook
Author
Publisher
Pages 100
Release 1981
Genre
ISBN

Download National Dam Inspection Program. Maple Lake Dam (NDI ID Number PA-01026, DER ID Number 57-38), Susquehanna River Basin, Branch of Blackwater Run, Sullivan County, Pennsylvania. Phase I Inspection Report Book in PDF, Epub and Kindle

Maple Lake Dam is an earthfill embankment 14.4 feet high and 283 feet long, excluding spillway. The emergency spillway is located at the left abutment, consisting of an earth channel having a trapezoidal cross section. The bottom width of the spillway at the reservoir outlet is 56 feet. A service spillway, consisting of a 12-inch riser pipe and an 8-inch diameter outlet pipe, is located approximately 100 feet from the right abutment. The outlet works was reported to consist of an 8-inch diameter asbestos cement pipe, extending upstream of the riser pipe to the reservoir and terminating with two sections of an 8-inch diameter vitrified clay pipe, having a concrete plug at the inlet. Based on visual inspection, the Maple Lake Dam is judged to be in good condition. Under the present conditions, the spillway will pass approximately 37 percent of the PMF. Should the top of the dam be restored to its design elevation, the spillway could pass the SDF without overtopping the dam.

Technical Abstract Bulletin

Technical Abstract Bulletin
Title Technical Abstract Bulletin PDF eBook
Author
Publisher
Pages 228
Release 1981
Genre Science
ISBN

Download Technical Abstract Bulletin Book in PDF, Epub and Kindle

National Dam Inspection Program. Hathaway Pond Dam (NDI ID Number PA 00050, PennDER Number 58-06), Susquehanna River Basin, West Branch of Lackawanna River, Susquehanna County, Pennsylvania. Phase I Inspection Report

National Dam Inspection Program. Hathaway Pond Dam (NDI ID Number PA 00050, PennDER Number 58-06), Susquehanna River Basin, West Branch of Lackawanna River, Susquehanna County, Pennsylvania. Phase I Inspection Report
Title National Dam Inspection Program. Hathaway Pond Dam (NDI ID Number PA 00050, PennDER Number 58-06), Susquehanna River Basin, West Branch of Lackawanna River, Susquehanna County, Pennsylvania. Phase I Inspection Report PDF eBook
Author John A. Dziubek
Publisher
Pages 72
Release 1981
Genre
ISBN

Download National Dam Inspection Program. Hathaway Pond Dam (NDI ID Number PA 00050, PennDER Number 58-06), Susquehanna River Basin, West Branch of Lackawanna River, Susquehanna County, Pennsylvania. Phase I Inspection Report Book in PDF, Epub and Kindle

Hathaway Pond Dam is located in Ararat Township, Susquehanna County, Pennsylvania. The reservoir was originally created to provide water for power purposes. The reservoir slopes are moderate with a good cover of vegetation. There are three ponds upstream from Hathaway Pond Dam on two tributary streams. The western stream contains Romobe Lake (PennDER I.D. No. 58-10) which is 1750 feet upstream from Hathaway Pond Dam. The eastern tributary contains Ball Lake and an unnamed smaller pond in series. Ball Lake is 2450 feet upstream and will retain considerable storage while the smaller unnamed pond was considered to have no effect on Hathaway Pond Dam. Two homes, a trailer, and township road are located 1800 feet downstream from Hathaway Pond Dam. These could suffer economic damage in the event of a dam failure.

National Dam Inspection Program. Longford Lake Dam (NDI ID Number PA- 00898, DER ID Number 58-137), Susquehanna River Basin, Tributary to Choconut Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report

National Dam Inspection Program. Longford Lake Dam (NDI ID Number PA- 00898, DER ID Number 58-137), Susquehanna River Basin, Tributary to Choconut Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report
Title National Dam Inspection Program. Longford Lake Dam (NDI ID Number PA- 00898, DER ID Number 58-137), Susquehanna River Basin, Tributary to Choconut Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report PDF eBook
Author
Publisher
Pages 79
Release 1981
Genre
ISBN

Download National Dam Inspection Program. Longford Lake Dam (NDI ID Number PA- 00898, DER ID Number 58-137), Susquehanna River Basin, Tributary to Choconut Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report Book in PDF, Epub and Kindle

The visual inspection and review of available design and construction data indicate that Longford Lake Dam is in good condition. In accordance with the guidance provided, the spillway design flood (SDF) ranges between 1/2 the PMF and the full PMF. Based on the size and extent of downstream hazard for the dam, the SDF selected for this facility was the PMF. The hydrologic and hydraulic computations indicate that the combination of reservoir storage and spillway discharge capacity will pass 88% of the PMF prior to overtopping the embankment. Therefore, in accordance with the recommended criteria for Phase I inspections, the spillway for Longford Lake Dam is considered to be inadequate.

National Dam Inspection Program. Bel-Air Lake Dam (NDI I.D. PA-0066, DER I.D. 058-116), Susquehanna River Basin, Tributary of Snake Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report

National Dam Inspection Program. Bel-Air Lake Dam (NDI I.D. PA-0066, DER I.D. 058-116), Susquehanna River Basin, Tributary of Snake Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report
Title National Dam Inspection Program. Bel-Air Lake Dam (NDI I.D. PA-0066, DER I.D. 058-116), Susquehanna River Basin, Tributary of Snake Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report PDF eBook
Author
Publisher
Pages 70
Release 1981
Genre
ISBN

Download National Dam Inspection Program. Bel-Air Lake Dam (NDI I.D. PA-0066, DER I.D. 058-116), Susquehanna River Basin, Tributary of Snake Creek, Susquehanna County, Pennsylvania. Phase I Inspection Report Book in PDF, Epub and Kindle

The condition of Bel-Air Lake Dam is considered to be unsafe/ nonemergency due to a seriously inadequate spillway capacity. The overall condition of the dam is considered to be fair. Although at this time no signs of significant distress were observed, it appears that the center of the dam has significantly settled. The design drawings show the design freeboard to be five feet, but the available freeboard is only approximately two feet. It also appears that fill has been placed on the downstream slope, increasing the crest width from the design value of 10 feet to about 30 feet near the center line of the dam and greater than 50 feet near the left abutment. The dam has no functional low level outlet facility.