Evaluation of the SSL MSE Plus Retaining Wall System
Title | Evaluation of the SSL MSE Plus Retaining Wall System PDF eBook |
Author | Highway Innovative Technology Evaluation Center (U.S.) |
Publisher | ASCE Publications |
Pages | 152 |
Release | 2001-01-01 |
Genre | Technology & Engineering |
ISBN | 9780784474716 |
Prepared by the Highway Innovative Technology Evaluation Center (HITEC), a CERF service center. This report describes a HITEC evaluation designed to determine the basic capabilities and limitations of the MSE Plus System, manufactured by SSL, LLC, for use as a mechanically stabilized earth retaining system. The evaluation was conducted based on material, design, construction, performance, and quality assurance information outlined in the HITEC Protocol. TheØMSE PlusØSystem features rectangular segmental precast concrete facing panels and galanized welded wire, grid-type soil reinforcement.
Evaluation of the Keysystem I Retaining Wall
Title | Evaluation of the Keysystem I Retaining Wall PDF eBook |
Author | Highway Innovative Technology Evaluation Center (U.S.) |
Publisher | ASCE Publications |
Pages | 136 |
Release | 2000-01-01 |
Genre | Technology & Engineering |
ISBN | 9780784474853 |
Prepared by the Highway Innovative Technology Evaluation Center (HITEC), a CERF Innovation Center. This report describes an evaluation to determine the capabilities and limitations of the KeySystem I Retaining Wall System, a mechanically stabilized earthØstructure developed, designed, and supplied by Keystone Retaining Wall Systems, Inc. The evaluation was conducted based on design, construction, performance, and quality assurance information outlined in the HITEC Protocol. KeySystem I features modular block facing to which KeyStrips are attached. KeyStrips are structural welded wire, grid-type reinforcement produced from high-strength steel.
Summary of Evaluation Findings for the Testing of Seismic Isolation and Energy Dissipating Devices
Title | Summary of Evaluation Findings for the Testing of Seismic Isolation and Energy Dissipating Devices PDF eBook |
Author | Highway Innovative Technology Evaluation Center (U.S.) |
Publisher | ASCE Publications |
Pages | 112 |
Release | 1999-01-01 |
Genre | Technology & Engineering |
ISBN | 9780784474679 |
Prepared by the Highway Innovative Technology Evaluation Center (HITEC), a CERF Service Center. his report summarizes the results of an evaluation that was designed to test the performance of 11 seismic isolators and dampers. The devices were tested for stability, response during earthquake simulations, and fatigue and weathering effects.
Evaluation of the Inter-Lok Retaining Wall System
Title | Evaluation of the Inter-Lok Retaining Wall System PDF eBook |
Author | Highway Innovative Technology Evaluation Center (U.S.) |
Publisher | ASCE Publications |
Pages | 130 |
Release | 2002-01-01 |
Genre | Technology & Engineering |
ISBN | 9780784475102 |
Prepared by the Highway Innovative Technology Evaluation Center (HITEC), a CERF/IIEC Innovation Center. This report describes a HITEC evaluation designed to determine the basic capabilities and limitations of the INTER-LOK System for use as a technically viable, precast mechanically stabilized earth retaining wall system. The evaluation was conducted based on design, construction, performance, and quality assurance information outlined in the HITEC Protocol. The INTER-LOK System features a cross-shaped, segmental precast concrete facing panel connected to metallic rebar and anchor plate type of soil reinforcement attached to the facing panels by a keyplate that interlocks with the facing panels.
Evaluation of the Maccaferri Terramesh System Retaining Wall
Title | Evaluation of the Maccaferri Terramesh System Retaining Wall PDF eBook |
Author | Highway Innovative Technology Evaluation Center (U.S.) |
Publisher | ASCE Publications |
Pages | 94 |
Release | 2002-01-01 |
Genre | Technology & Engineering |
ISBN | 9780784475201 |
Prepared by the Highway Innovative Technology Evaluation Center (HITEC), a CERF/IIEC Innovation Center. This report describes a HITEC evaluation designed to determine the basic capabilities and limitations of the Terramesh Retaining Wall System for use as a technically viable, mechanically stabilized earth, retaining wall system. The evaluation was conducted based on material, design, construction, performance, and quality assurance mainformation outlined in the HITEC Protocol. The Terramesh System, supplied by Maccaferri, Inc.,Øfeatures a Gabion basket facing of various configurations and metal double-twisted grid type of soil reinforcement, which is manufactured integrally with the basket facing blocks.
Evaluation of the Trevipark Automated Parking System
Title | Evaluation of the Trevipark Automated Parking System PDF eBook |
Author | Highway Innovative Technology Evaluation Center (U.S.) |
Publisher | ASCE Publications |
Pages | 110 |
Release | 2001-01-01 |
Genre | Technology & Engineering |
ISBN | 9780784475034 |
Prepared by the Civil Engineering Innovative Technology Evaluation Center, a CERF innovation center serving the engineering and construction industries. This report presents a CEITEC evaluation of the Trevipark automated parking system, which was developed, designed, and supplied by TREVI S.p.A., of Cesena, Italy. The evaluation is designed to determine the benefits and limitations of Trevipark for use as a technically viable automated vehicle parking system. The evaluation focused on data collection, site inspections, and analyses. The Trevipark system consists of a cylindrical enclosure with a central elevator system to park and store vehicles in a radial pattern. This proprietary system is intended to provide safe and secure parking for lower cost, smaller site and space requirements, less retrieval time, and other advantages.
Evaluation of the Tricon Retained Soil Wall System
Title | Evaluation of the Tricon Retained Soil Wall System PDF eBook |
Author | Highway Innovative Technology Evaluation Center (U.S.) |
Publisher | ASCE Publications |
Pages | 142 |
Release | 2002-01-01 |
Genre | Technology & Engineering |
ISBN | 9780784475171 |
Prepared by the Highway Innovative Technology Evaluation Center, a CERF/IIEC Innovation Center. This report describes a HITEC evaluation designed to determine the basic capabilities and limitations of the Tricon System for use as a technically viable, precast, mechanically stabilized earth-retaining wall system. The evaluation considered material, design, construction, performance, and quality assurance information outlined in the HITEC Protocol.