WIDE-RANGE PLUTONIUM ISOTOPIC ANALYSIS WITH CDTE DETECTOR.

WIDE-RANGE PLUTONIUM ISOTOPIC ANALYSIS WITH CDTE DETECTOR.
Title WIDE-RANGE PLUTONIUM ISOTOPIC ANALYSIS WITH CDTE DETECTOR. PDF eBook
Author
Publisher
Pages
Release 2001
Genre
ISBN

Download WIDE-RANGE PLUTONIUM ISOTOPIC ANALYSIS WITH CDTE DETECTOR. Book in PDF, Epub and Kindle

Testing the Plutonium Isotopic Analysis Code FRAM with Various CdTe Detectors

Testing the Plutonium Isotopic Analysis Code FRAM with Various CdTe Detectors
Title Testing the Plutonium Isotopic Analysis Code FRAM with Various CdTe Detectors PDF eBook
Author
Publisher
Pages 5
Release 2002
Genre
ISBN

Download Testing the Plutonium Isotopic Analysis Code FRAM with Various CdTe Detectors Book in PDF, Epub and Kindle

The isotopic analysis code Fixed-energy Response-function Analysis with Multiple efficiency (FRAM)1,2 has been proven to successfully analyze plutonium spectra taken with a portable CdTe detector with Peltier cooling, the first results of this kind for a noncryogenic detector. 3 These are the first wide-range plutonium gamma-ray isotopics analysis results obtained with other than Ge spectrometers. The CdTe spectrometer measured small plutonium reference samples in reasonable count times, covering the range from low to high burnup. This paper describes further testing of FRAM with two CdTe detectors of different sizes and resolutions using different analog and digital, portable multichannel analyzers (MCAs).

APPROACHING CRYOGENIC GE PERFORMANCE WITH PELTIER COOLED CDTE.

APPROACHING CRYOGENIC GE PERFORMANCE WITH PELTIER COOLED CDTE.
Title APPROACHING CRYOGENIC GE PERFORMANCE WITH PELTIER COOLED CDTE. PDF eBook
Author
Publisher
Pages 10
Release 2001
Genre
ISBN

Download APPROACHING CRYOGENIC GE PERFORMANCE WITH PELTIER COOLED CDTE. Book in PDF, Epub and Kindle

A new class of hand-held, portable spectrometers based on large area (lcm2) CdTe detectors of thickness up to 3mm has been demonstrated to produce energy resolution of between 0.3 and 0.5% FWHM at 662 keV. The system uses a charge loss correction circuit for improved efficiency, and detector temperature stabilization to ensure consistent operation of the detector during field measurements over a wide range of ambient temperature. The system can operate continuously for up to 8hrs on rechargeable batteries. The signal output from the charge loss corrector is compatible with most analog and digital spectroscopy amplifiers and multi channel analyzers. Using a detector measuring 11.2 by 9.1 by 2.13 mm3, we have recently been able to obtain the first wide-range plutonium gamma-ray isotopic analysis with other than a cryogenically cooled germanium spectrometer. The CdTe spectrometer is capable of measuring small plutonium reference samples in about one hour, covering the range from low to high burnup. The isotopic analysis software used to obtain these results was FRAM, Version 4 from LANL. The new spectrometer is expected to be useful for low-grade assay, as well as for some in-situ plutonium gamma-ray isotopics in lieu of cryogenically cooled Ge.

Plutonium and Uranium Isotopic Analysis

Plutonium and Uranium Isotopic Analysis
Title Plutonium and Uranium Isotopic Analysis PDF eBook
Author
Publisher
Pages
Release 1999
Genre
ISBN

Download Plutonium and Uranium Isotopic Analysis Book in PDF, Epub and Kindle

The Lawrence Livermore National Laboratory develops sophisticated gamma-ray analysis codes for isotopic determinations of nuclear materials based on the principles of the MultiGroup Analysis (MGA). MGA methodology has been upgraded and expanded and is now comprised of a suite of codes known as MGA++. A graphical user interface has also been developed for viewing the data and the fitting procedure. The code suite provides plutonium and uranium isotopic analysis for data collected with high-purity germanium planar and/or coaxial detector systems. The most recent addition to the MGA++ code suite, MGAHI, analyzes Pu data using higher-energy gamma rays (200 keV and higher) and is particularly useful for Pu samples that are enclosed in thick-walled containers. Additionally, the code suite can perform isotopic analysis of uranium spectra collected with cadmium-zinc-telluride (CZT) detectors. We are currently developing new codes with will integrate into the MGA++ suite. These will include Pu isotopic analysis capabilities for data collected with CZT detectors, and U isotopic analysis with high-purity germanium detectors, which utilizes only higher energy gamma rays. Future development of MGA++ will include a capability for isotopic analyses on mixtures of Pu and U.

A New One-detector Analysis Method for Rapid High Precision Plutonium Isotopic Measurements

A New One-detector Analysis Method for Rapid High Precision Plutonium Isotopic Measurements
Title A New One-detector Analysis Method for Rapid High Precision Plutonium Isotopic Measurements PDF eBook
Author
Publisher
Pages
Release 1986
Genre
ISBN

Download A New One-detector Analysis Method for Rapid High Precision Plutonium Isotopic Measurements Book in PDF, Epub and Kindle

A new method has been developed that achieves plutonium isotopic analysis precisions of better than 2% in counting times of only a few minutes, using only the 59- to 208-keV energy region of a spectrum. This breakthrough was achieved by developing a unique but highly accurate method for delineating the overall ''intrinsic'' efficiency curve, including the plutonium K-shell absorption discontinuity at 121 keV. Consequently, the measured 129- and 148-keV peak intensities can now be used to reliably determine the relative abundances of 239Pu and 241Pu. The intense 94- to 104-keV region is also analyzed, providing accurate data for the other isotopes of interest. 5 refs., 3 figs., 2 tabs.

Uranium and Plutonium Isotopic Analysis Using MGA+

Uranium and Plutonium Isotopic Analysis Using MGA+
Title Uranium and Plutonium Isotopic Analysis Using MGA+ PDF eBook
Author
Publisher
Pages
Release 1998
Genre
ISBN

Download Uranium and Plutonium Isotopic Analysis Using MGA+ Book in PDF, Epub and Kindle

The Lawrence Livermore National Laboratory develops sophisticated gamma-ray analysis codes for the isotopic analysis of nuclear materials based on the principles used in the original MultiGroup Analysis (MGA) code. Over the years, the MGA methodology has been upgraded and expanded far beyond its original capabilities and is now comprised of a suite of codes known as MGA++. The early MGA code analyzed Pu gamma-ray data collected with high-purity germanium (HPGe) detectors to yield Pu isotopic ratios. While the original MGA code relied solely on the lower-energy gamma rays (around 100 keV), the most recent addition to the MGA++ code suite, MGAHI, analyzes Pu data using higher-energy gamma rays (200 keV and higher) and is particulatly useful for Pu samples - that are enclosed in thick-walled containers. The MGA++ suite also includes capabilities to perform U isotopic analysis on data collected with either HPGe or cadmium-zinc-tellutide (CZT) detectors. These codes are commercially available and are known as U235 and CZTU, respectively. A graphical user interface has also been developed for viewing the data and the fitting procedure. In addition, we are developing new codes that will integrate into the MGA++ suite. These will include Pu isotopic analysis capabilities for data collected with CZT detectors, U isotopic analysis with HPGe detectors which utilizes only higher energy gamma rays, and isotopic analyses on mixtures of Pu and U.

Deterioration of Plutonium Isotopic Analysis with Neurtron Damage to HPGe Detectors

Deterioration of Plutonium Isotopic Analysis with Neurtron Damage to HPGe Detectors
Title Deterioration of Plutonium Isotopic Analysis with Neurtron Damage to HPGe Detectors PDF eBook
Author
Publisher
Pages 8
Release 1991
Genre
ISBN

Download Deterioration of Plutonium Isotopic Analysis with Neurtron Damage to HPGe Detectors Book in PDF, Epub and Kindle

The effects of neutron (n) damage on HPGe detectors used to measure Pu isotopic ratios were investigated. Both a p-type planar and an n-type coaxial detector were progressively neutron damaged up to a total integrated flux of>5 x 109 n/cm2 from a 252Cf source. Severe deterioration of selected peak shapes and degradation in the Pu isotopic analysis capability were observed and quantified by using the GRPANL and MGA codes developed at LLNL. After an integrated exposure of 1 x 109 n/cm2 the Pu spectrum from the coaxial detector could not be analyzed with MGA. The planar detector spectrum continued to be analyzable with MGA up to 4 x 109 n/cm2. Cooling the planar detector to 80 K with an electrically-cooled cryostat could extent its useful lifetime up to an exposure of 2 x 101° n/cm2. 11 refs., 7 figs., 1 tab.